Feature:

  • The lightest and smallest among the gensets with same output
  • Full automatic generator protection system
  • Special dual protection system
  • Unique unloading system for stopping the generator
  • Steady frequency-governing ratio ≤ 3%, complying with military standard
  • Automatic Voltage Regulation for maintaining steady voltage
  • Automatic transfer switching, remote monitoring, to realize guardless by human
  • Low noise, only 70dB/7m 
  • New patent design,low inner housing temperature,stable output and good reliability

Options:Automatic Transfer Switch; R485 connection dimension;pre-heater

 

Specification: 

Model

WS12000LTA3

Rated frequency (Hz)

50       60

Rated output power (kVA)

11       12

Max. power (Kva)

12     13

Rated voltage (V)

400/230 416/240

Rated current (A)

15.9     16.7

Phase No.

Three

Power factor

0.8 (lag)

Insulation

F

Pole No.

2

Exciting way

Brush, exciting-self voltage-constant (with AVR)

Panel type

Intelligent

Output socket

Three-phase socket, single-phase socket

DC12V output

12V, 8.3A

Dimensions L×W×H mm

1040×660×740

Net weight Kg

245

Noise (7m)dB(A)

70

Structure type

Fully closed

Engine model

R2V840

Type

V-twin, two-cylinder, four-stroke, DI

Cylinder No. –bore ×stroke (mm)

2-86×72

Total displacement (ml)

836

Compressed ratio

20:1

Cooling way

Air-cooled

Lubricating way

Pressure & splashing

Starting way

Electric

Fuel used

0 # (summer ) -10 # (winter) -35 # (cold winter) light diesel

Oil used

SAE10W30 (CD grade above)

Lubricating oil capacity (L)

1.7

Starting motor capacity (V-kW)

12V  1.4kW

Dynamo capacity (V-A)

12V   8.3A

Battery capacity (V-Ah)

12V  45AH

Fuel consumption under full loading  L/H

3.5    4

Fuel tank capacity  L

21

Continuous running time  H

 6.0          5.3