Feature:

Silent, low noise (about 70 dB / 7m)
Compact structure with strong output power (lightest and smallest among the diesel generator sets with compatible output)
Intelligent control panel and full automatic generator protection system.
Steady frequency-governing ratio ≤ 3%, complying with military standard
Automatic Voltage Regulation for maintaining steady voltage \
Unique Patent design for separate cold / heat wind passage, ensure low inner housing temperature, stable output and good reliability
Digital diesel generator control panel
Fuil automatic protection
The dual-chip protection

---Intelligent Control panel
With the new-type intelligent control panel we adopt, the operator can know the real working condition of the
generator from panel reading. There are more than ten protections of the generator in the panel, such as protections of
frequency, voltage, current, low oil pressure, low fuel level, and electric fan adjusting the temperature automatically when inner-housing temperature is high, and automatic unload before engine stopped each time etc.

---ATS
Our company can fit ATS based on customer requirement, which can make the generator be automatic operation without the operator on the spot.
When city power net breaks down, ATS can deliver the signal in shortest time to the generator for starting. When city power net is recovered,
ATS can shift the power from the generator to city power net

 

Specification: 

Model

WS12000LTA3

Rated frequency (Hz)

50       60

Rated output power (kVA)

11       12

Max. power (Kva)

12     13

Rated voltage (V)

400/230 416/240

Rated current (A)

15.9     16.7

Phase No.

Three

Power factor cosφ

0.8lag

Insulation

F

Pole No.

2

Exciting way

Brush, exciting-self voltage-constant with AVR

Panel type

Intelligent

Output socket

Three-phase socket, single-phase socket

DC12V output

12V, 8.3A

DimensionsL×W×H mm

1040×660×740

Net weight Kg

245

Noise 7mdB(A)

70

Structure type

Fully closed

Engine model

R2V840

Type

V-twin, two-cylinder, four-stroke, DI

Cylinder No. bore ×stroke (mm)

2-86×72

Total displacement (ml)

836

Rated power kW/ rated speed r/min

11/3000  12/3600

Compressed ratio

20:1

Cooling way

Air-cooled

Lubricating way

Pressure & splashing

Starting way

Electric

Fuel used

0summer-10winter-35cold winter                light diesel

Oil used

SAE10W30CD grade above

Lubricating oil capacity (L)

1.7

Starting motor capacity (V-kW)

12V  1.4kW

Dynamo capacity (V-A)

12V  8.3A

Battery capacity (V-Ah)

12V  45AH

Fuel consumption (g/kW.h)

≤285      ≤320

Fuel tank capacity of the generator (L)

21

Continuous operation time of the  generator(H)

3.5      4.0